IntelliTone™ Pro 200 LAN Toner, Tracer, and Probe
Product Highlights
Digital network cable toner and probe traces and locates cables on active networks.
IntelliTone digital toning technology:
- Ends network cable location confusion, decisively rejects noise and false signals.
- Network cable tracer locates cables on active networks, even when terminated at a switch.
- Isolates cable and wiring within a bundle, despite cable bleed.
- Confirms cable location, verifies cable continuity, and detects cable faults (opens, shorts, and reversed pairs) in one step.
- Signal strength indicator LEDs help you identify one cable that is bundled with other cables.
- Probe has built-in pair tester to identify open, shorted, and crossed pairs. View More >
SmartTone® analog toning technology:
- Isolates individual wire pairs precisely by changing tone when shorted.
- Effectively traces and locates voice, audio, and video cabling.
PRODUCT NAVIGATION
Overview
What Is a Digital Network Cable Toner and Probe?
Network cable toners and probes are the most effective way to trace the electrical cables hidden in building walls, floors, and ceilings. A good cable tester and toner tracks electrical signals to locate internet cables, Ethernet wires, phone lines, and other key wires.
One of the toughest challenges technicians face is identifying individual cables that are bundled with other cables. With both digital and analog signaling, the IntelliTone Pro eliminates the guesswork and allows even inexperienced teams to easily trace and identify individual wires on active networks.
The IntelliTone’s built-in pair tester identifies open, shorted, and crossed pairs. Its signal strength indicator LEDs let you easily identify individual cables that are bundled with other cables. And its unique SmartTone™ analog toning technology changes tone to isolate individual wire pairs.
What Is the Advantage of Combining Both Analog and Digital Signaling in One Tool?
Modern media networks are highly complex. It’s typical for buildings to have telephone, twisted-pair data, coax, and security/alarm wiring bundled in closets or hidden behind walls.
Our IntelliTone Pro LAN Toner and Probe can trace and organize even the most diverse wiring. It offers both analog and digital signaling, making it a powerful all-in-one tool that combines all the cable tracing technologies you need, for any setting.
Trace and track data cabling with IntelliTone’s digital mode. Use the analog mode to locate individual wire pairs, and to trace and locate voice, audio, and video cabling.
Can the IntelliTone Pro Tone on Live Networks?
Yes. The IntelliTone Pro cable toner tester is fast and effective in virtually any setting, including on active networks. Its digital signal retains its strength even when dealing with common mode termination. And the IntelliTone Pro automates toning individual cable conductors, making it quick, efficient, and safe to locate cables on active networks.
Testing Network Cable with the IntelliTone Pro
The IntelliTone Pro offers advanced vision for tracing and locating network cables more effectively at patch panels, switches, termination blocks, or hidden within bundles. IntelliTone finds the cables that others can't.
The IntelliTone Pro 200 LAN Toner and Probe Series from Fluke Networks is designed to be an intuitive, all-purpose network cable toner, tracer, and probe, with digital and analog signaling in one tool. That means it offers reliable cable tracing and location technologies for any work environment. Use its digital mode to trace and locate data cabling safely and effectively on active networks. Use the analog mode to isolate individual wire pairs, and trace voice, audio, and video cabling.
The IntelliTone Pro offers built-in solutions to common challenges. Digital signal processing rejects noise and false signals. SmartTone analog signal locates individual wire pairs. Test for continuity, locate missing cables, and verify Ethernet service with ease.
Features
Only IntelliTone™ Pro Toners and Probes offer the powerful combination of digital and analog technologies to resolve common infrastructure problems that arise during installing, maintaining, and changing of your network.
Digital and analog toning in one tool.
Today’s media networks are more diverse than ever. Most buildings have a combination of telephone, twisted-pair data, coax, and security/alarm wiring. Verifying proper routing and termination of this diverse set of cabling types requires tools optimized for different frequencies, connector types, and work environments. Until now, no single tool has combined the right technologies to operate across all copper media types, and in all environments. IntelliTone Pro changes that by combining cutting-edge digital and analog signaling to locate and verify virtually any copper cable, regardless of application or environment.
When to use digital
IntelliTone Pro’s digital encoded signal should primarily be used on high-grade data cabling (Cat 5e/6/6a), and in active network environments. It operates at a high-frequency to match the higher frequency data the cable plant is designed to carry. This allows the tone to overcome competing data signals and aggressive low-frequency terminations of Ethernet switches. That means LAN cabling technicians can quickly zero in on the right cable during installations or troubleshooting.
Digital toning is especially helpful once the cable has been located as it displays cable wiremap and checks for shorts, opens and miswires. The IntelliTone Pro 200 probe has an RJ45 input port and CableMap feature, allowing it to be plugged directly into a patch panel or wall port. The benefit of this wiremap test is two-fold. It eliminates the need for both a toner to a wiremapper, and provides 100% confirmation that the right cable has been located.
When to use analog
IntelliTone Pro’s SmartTone analog toning can be used on voice-grade cabling (Cat 3 and below), as well as coax, security/alarm, and speaker wiring. These cables are optimized for lower frequency transmissions, and therefore are more easily isolated with a low-frequency tone. It should also be used in areas with relatively low interference from electronic devices. In high-interference environments, digital may still be a better choice.
SmartTone analog toning eliminates frustrating guesswork locating individual wire pairs during installations. The SmartTone analog signal will change ‘songs’ each time the pair under test is shorted together. This provides telecom technicians a decisive way to identify individual wire pairs before punching them down on a jack or a block, or when diagnosing voice transmission problems.
Isolate Terminated Cables
The IntelliTone™ Pro Toner uses the unique properties of twisted pair cabling to create a balanced signal that minimizes the effect of signal bleed. The smart digital signal processing in the IntelliTone™ Pro Probe clearly identifies this signal with audio and LED visual indicators, allowing you to rapidly isolate the correct cable from a bundle or on a patch panel. IntelliTone™ eliminates hours of cable confusion—and you can count on getting it right the first time.
Isolate Individual Wire Pairs
With traditional analog toners and probes, isolating individual wire pairs precisely can be almost impossible because of signal bleed between pairs. As a result, wire pairs are often routed and terminated incorrectly the first time. Redoing incorrect terminations or pulling new wiring wastes tremendous amounts of time and money. IntelliTone Pro’s SmartTone analog technology cuts out the guesswork and improves accuracy by providing definitive confirmation when the pair under test is located. Just short the pair under test, and the audible tone will change its cadence. The difference is dramatic.
Eliminate callbacks during cabling moves, adds and changes with the powerful diagnostic capabilities of IntelliTone. The IntelliTone Pro 200 Probe features a CABLEMAP capability that identifies common cable miswires in twisted pair cabling. IntelliTone technology automates the testing of each conductor for end-to-end continuity; LED lights and tones clearly indicate miswires such as opens, shorts or reversed pairs.
Modern network devices use aggressive termination schemes for cables connected to their ports. While this termination reduces noise and crosstalk in the cable, it can also absorb an analog toner signal, making the connected cable impossible to detect with an analog audio probe. The result is that locating an unlabeled network can take hours with analog technology. Unlike analog signals, the IntelliTone digital signal stays strong despite common mode termination. And the IntelliTone Pro Toner automates toning individual cable conductors, making it quick, efficient and safe to locate cables on active networks.
Perform moves, adds and changes with powerful diagnostic capabilities of the IntelliTone Pro 200 Toner & Probe
Toning - IntelliTone makes it easy to quickly locate the cable in the equipment closet when performing moves, adds and changes. Unconnected cable can be quickly isolated in the presence of bleed.
Cablemap - The IntelliTone Pro 200 Probe features a CABLEMAP capability that identifies common cable miswires in twisted pair cabling. Complete per-pin verification of TIA568 wiring identifies the exact wire that is open, shorted or miswired. LED lights and distinctive tones clearly indicate miswires. The built-in Cablemap feature eliminates the need to carry separate tools or returning to the far-end to replace the toner with a mapper. The IntelliTone Pro 200 Kit is the all-in-one tool to locate and map Category 5 cabling even when plugged into a switch, and verify link service after moves, adds and changes.
Verify Ethernet Service - Is the link pulse correct, reversed due to a swap cable of uplink port, or MDIX capable? Identify active Ethernet services present at the office wallplate. LED lights clearly indicate the presence of normal, reversed or MDIX Ethernet link connectivity.
Models & Accessories
Models
Accessories
Specifications
GENERAL SPECS
Operating temperature
32 °F to 104 °F (0 °C to 40 °C)
Storage temperature
-4 °F to +140°F (-20 °C to °C)
Operating relative humidity (% RH without condensation)
95 % (50 °F to 95 °F; 10 oC to 35 °C)
75 % (95 °F to 104 °F; 35 °C to 40 °C) Uncontrolled < 50 °F (< 10 °C)
Vibration
Random, 2 g, 5 Hz-500 Hz
Shock
1 m drop test
Safety
EN 61010-1, Category: None
Altitude
3000 m
EMC
EN 61326-1, FCC Part 15 B
Battery type and life
9 V alkaline (NEDA 1604A or IEC 6LR61); 20 hours typical
Applications
Copper cabling media including; 75 or 50 Ohm Coaxial cable; Two Conductor control, security, generic cabling. 10 Base-T or 10/100 Base-T datacom networks. UTP cable. Shielded Twisted Pair supported in Cablemap function of the IntelliTone 200.
TONER SPECS
Dimensions
5.54 in x 2.94 in x 1.25 in (14.1 cm x 7.5 cm x 3.2 cm)
Display
LED
Control
Thumbwheel switch
Toner interface
Main Mod8 port for tone generation on all 4 pairs of UTP / STP cabling. F Connector for coaxial cabling Banana Jack Plugs (2) - two conductor wiring
Toner frequency
IntelliTone™ signal: encoded digital signal
Analog SmartTone signal: 500 - 1200Hz, 4 songs
Ouptut power
5 V p-p
Auto power down
Turns off automatically after 2 1/2 hours of inactivity
PROBE SPECS
Dimensions
8.73 in x 1.88 in x 1.26 in (22.2 cm x 4.8 cm x 3.2 cm)
Display
(8) LED indicators, Sync LED indicator
Audio
IntelliTone: Microprocessor controlled audio files
Analog: Detected toner signal
Control
Thumbwheel switch, volume control wheel
Tone detection
Detects IntelliTone™ digital signal for Locate, Isolate, and CableMap
Detects analog SmartTone signal (500-1200Hz) and other analog toners.
Cable Port
Main Mod8 port for cablemap on all 4 pairs of UTP / STP cabling.
Auto power down
Turns off automatically after 1 hour of inactivity