TS® 19 Test Sets
PRODUCT NAVIGATION
Overview
The Fluke Networks TS19 Test Set combines all the essential test set features at an affordable price. This test set was specifically designed for in-house telecom technicians. Its high impedance monitor prevents accidental disruption of service from clipping onto a data line while in monitor mode, thus ensuring the integrity of critical data lines. Features such as tone (DTMF) or pulse operation, talk/monitor capabilities, polarity test button and last number redial make this test set the perfect combination of features and price.
TS® Professional Series – Products Comparison
Features
Models & Accessories
Specifications
Electrical
Loop Limit
2.4 kΩmaximum at 48 VDC (nominal 15 mA minimum loopcurrent)
DC Resistance (Talk Mode)
150 Ωtypical at 80 mA current
AC Impedance (Monitor Mode)
Low impedance (Ring position) 600 Ωat 1 KHz typical
High impedance (HI Z position) 100 kΩminimum at 1 KHz
Rotary Dial Output
10 pps .5 pps
Pulsing Rate
60 % ± 2 %
Percent Break
800 ms typical
Interdigit Interval Leakage During Break
> 50 kΩ
DTMF Output
±1 % maximum
Tone Frequency Error Level per Tone Pair
dBm maximum, - dBm minimum
High versus Low Tone Difference
4 dB maximum
Physical
Length
8.75 in (22.2 cm)
Width
2.375 in (6.03 cm)
Height
3.375 in (8.57 cm)
Weight
10.8 oz (.307 kg) maximum
Environmental
Temperature
Operating: -5 °C to °C
Storage: -40 °C to °C
Drop
1 meter, 4 times
Altitude
To 3,000 meters (10,000 feet) maximum
Relative Humidity
10 %to 80 % (non-condensing)
Regulatory Standards Used
47 CFR Part 15, Subpart B
ICES-003 Issue 3
AS/NZS 3548
EMC Directive 89/336/EEC, EN 55022:98, EN 61326:97, A1:98 Annex C, EN 61000-4-2, EN 61000-4-3
LV Directive 73/23/EEC, EN 610010.1 (1993)
Certifications and Compliance
CAN/CSA-C22.2 No. 60950-1-03
CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1