CertiFiber® Pro Optical Loss Test Set
Product Highlights
Accelerates every step of the fiber certification process
- Optical loss test set with fastest time to certify – two fibers at two wavelengths in under three seconds.
- Encircled Flux compliant as required by ANSI/TIA and ISO/IEC
- Merged Tier 1 (Basic) / Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR
- ProjX™ management system ensures all jobs are completed correctly and efficiently
- Optical loss test set provides automatic Pass/Fail analysis to industry standards or custom test limits View More >
- Double ended Pass/Fail certification of fiber optic connector endfaces
- Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
- Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Taptive™ user interface provides simple, animated guidance to eliminate incorrect reference setup and “negative loss” errors.
- Convenient quad module supports both multimode and singlemode loss testing
- Extended singlemode distance range to 130km
- Optical loss test set with built in Visual Fault Locator
- Analyze test results and create professional test reports using LinkWare™ Management Software
- Compatible with LinkWare™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software
PRODUCT NAVIGATION
Overview
The CertiFiber Pro Optical Loss Test Set improves the efficiency of fiber optics certification. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. A set reference wizard ensures correct reference setting and eliminates negative loss errors. Built on the future-ready Versiv platform, CertiFiber Pro Optical Loss Test Set (OLTS) provides merged Tier 1 (Basic) / Tier 2 (Extended) testing and reporting when paired with OptiFiber Pro module. A convenient quad module supports both singlemode and multimode and is multimode Encircled Flux compliant. Copper certification and Wi-Fi Analysis and Ethernet troubleshooting modules are also available. Analyze test results and create professional test reports using LinkWare Management Software.
CertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification, takes the guess work out of fiber inspection so anyone can be a fiber expert.
Features
Unique Features:
- Versiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process
- ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.
- Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.
- LinkWare management software provides unmatched analysis of test results and professional test reports
Standards:
- Allows combined OLTS Tier 1 (basic), OTDR Tier 2 (extended) certification, end-face inspection and reporting when paired with OptiFiber™ Pro OTDR
- Set reference wizard verifies test reference cords (TRCs) per ISO/IEC 14763-3 and eliminates negative loss errors
- Encircled Flux compliant optical launch conditions required by ANSI/TIA and ISO/IEC standards
- Double ended fiber optic end-face certification to IEC 61300-3-35
Performance:
- Three-second Autotest – (four times faster than legacy testers) includes optical loss measurement of two fibers at two wavelengths with distance measurement and optical loss budget calculation
- Provides automatic Pass/Fail analysis to industry standards or custom test limits
- Identifies incorrect test procedures resulting in negative loss results
- Double ended Pass/Fail certification of fiber optic connector end-faces
- Graphical indication of problem areas on fiber end-faces due to contamination, pits, chips and scratches
- Interchangeable power meter adapters available for all typical connector types (SC, ST, LC and FC) to enable the most accurate 1-jumper reference method
- Built-in visual fault locator for basic troubleshooting and polarity determination
- Dual wavelength measurement capability on a single fiber allows the tester to be used in applications that require only one fiber link.
- Compliant with TIA-526-14-B and IEC 61280-4-1 Encircled Flux requirements with no additional equipment or procedures
- Integrated Wi-Fi allows you to easily upload results to LinkWare Live
Versiv’s ProjX™ System manages jobs from set-up to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email.
Set-up or view test limits, fiber types, and testing attributes. | View multiple projects. | Select a project icon to see specific detail. |
Versiv is driven by Taptive, the most advanced user interface for a field tester. With a gestured based interface, technicians and project managers of all skill levels can eliminate costly errors and do more faster with fewer key strokes, set-up wizards, swiping, pinch to zoom, and access to more data right at their fingertips.
Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. |
Managing test results and creating professional test reports is the legacy of LinkWare, giving Project Managers full capabilities to monitor workflow and consolidate test results.
LinkWare PC pulls data together into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare Stats feature in LinkWare PC, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.
Encircled Flux and Test Reference Cords Tested. |
LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device. With LinkWare Live, you can
- Keep track of every test on every job. Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
- Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
- Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
- Stop wasting time and gas driving testers back to the office. Integrated Wi-Fi allows you to upload your test results straight from the job site to LinkWare Live. Then download them automatically to the right job for fast report generation with LinkWare PC.
- Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
- Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.
*See supported countries.
Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminants cause insertion loss and back-reflection that inhibit optical transmission and causes havoc with transceivers. Fiber loss testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate. Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected.
CertiFiber Pro Optical Loss Test Set (OLTS) provides double ended fiber optic inspection capability through the use of 2 Versiv Main units. One unit acts as the normal CertiFiber Pro main and the 2nd unit functions as a Remote unit. Using a Main unit as a Remote provides a touchscreen interface at the Remote end giving you the ability to visually inspect fiber end-faces!
CertiFiber Pro’s double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification, takes the guess work out of fiber inspection so anyone can be a fiber expert.
Fluke Networks Test Reference Cords and Launch Fibers with LC connectors feature our unique metal latch design. Traditional LC connectors use a single-piece plastic design that flexes the latching mechanism each time the connector is inserted and removed and eventually breaks, making them unsuitable for repeated use in testing. The Fluke Networks Metal LC latching system uses a multi-piece metal design with a spring located between the latch and connector body. Since this latch is not part of the body and does not flex, the life of the latching mechanism is greatly improved, thereby extending the life of the LC connector and therefore the TRC’s and launch cords.
The Metal LC connector is compliant with IEC 61754-20 and TIA-604-10B intermateability standards. That latch has also been tested for up to 10,000 insertions with no degradation in performance and passes all Telecordia GR-326-CORE durability tests including thermal, humidity, vibration, flex, impact, and salt spray. While the connector itself is the most rugged available, the glass fiber endface is still susceptible to damage, so it’s important to inspect the endface to make sure it’s contaminant-free and to properly clean it if necessary.
Models & Accessories
Models
CFP2-100-M-NW Gold Support
Same configuration as the CFP2-100-M with integrated Wi-Fi disabled.See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-M
1 year of Gold Support for CFP2-100-M, CFP2-100-M-NW, CFP-100-M-W or CFP-100-M
GLD3-CFP-100-M
3 years of Gold Support for CFP2-100-M, CFP2-100-M-NW, CFP-100-M-W or CFP-100-M
CFP2-100-S-NW Gold Support
Same configuration as the CFP2-100-S with integrated Wi-Fi disabled.See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-S
1 year of Gold Support for CFP2-100-S, CFP2-100-S-NW, CFP-100-S-W or CFP-100-S
GLD3-CFP-100-S
3 years of Gold Support for CFP2-100-S, CFP2-100-S-NW, CFP-100-S-W or CFP-100-S
CFP2-100-Q-NW Gold Support
Same configuration as the CFP2-100-Q with integrated Wi-Fi disabled. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-Q
1 year of Gold Support coverage for CFP2-100-Q, CFP2-100-Q-NW, CFP-100-Q-W or CFP-100-Q
GLD3-CFP-100-Q
3 years of Gold Support coverage for CFP2-100-Q, CFP2-100-Q-NW, CFP-100-Q-W or CFP-100-Q
CFP-Q-ADD Gold Support
CertiFiber Pro Add on Kit – includes (2) CertiFiber Pro Quad OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, Large Carry Case, Statement of Calibration and Getting Started Guide. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-Q-ADD
1 year of Gold Support coverage for CFP-Q-ADD
GLD3-CFP-Q-ADD
3 years of Gold Support coverage for CFP-Q-ADD
CFP2-Q-ADD-R Gold Support
CertiFiber Pro Add on Kit with Remote – includes 1 Versiv 2 Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Large Carry Case, AC Chargers, Statement of Calibration and Getting Started Guide. (Requires a Versiv 2 mainframe) See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-Q-ADD-R
1 year of Gold Support coverage for CFP2-Q-ADD-R or CFP-Q-ADD-R
GLD3-CFP-Q-ADD-R
3 years of Gold Support coverage for CFP2-Q-ADD-R or CFP-Q-ADD-R
CFP-MM-ADD Gold Support
(2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 µm, TRC Carrying Case, (2) LC/LC Adaptors, Large Carry Case, Statement of Calibration and Getting Started Guide. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-MM-ADD
1 year of Gold Support coverage for CFP-MM-ADD which includes CertiFiber Pro Multimode
GLD3-CFP-MM-ADD
3 years of Gold Support coverage for CFP-MM-ADD which includes CertiFiber Pro Multimode
CFP-SM-ADD Gold Support
(2) CertiFiber Pro Singlemode OLTS Modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adaptors, Large Carry Case, Statement of Calibration and Getting Started Guide. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-SM-ADD
1 year of Gold Support coverage for CFP-SM-ADD which includes CertiFiber Pro Singlemode OLTS module
GLD3-CFP-SM-ADD
3 years of Gold Support coverage for CFP-SM-ADD which includes CertiFiber Pro Singlemode OLTS module
The CertiFiber Pro models are available in 2 versions: wireless and non-wireless. The Wireless version includes integrated Wi-Fi for for uploading results to LinkWare Live. The integrated Wi-FI is disabled in the non-wireless version for customers who do not wish to receive Wi-Fi.
CFP2-100-M Gold Support
1 Versiv Mainframe & Remote, (2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 um, TRC Carrying Case, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-M
1 year of Gold Support for CFP2-100-M, CFP2-100-M-NW, CFP-100-M-W or CFP-100-M
GLD3-CFP-100-M
3 years of Gold Support for CFP2-100-M, CFP2-100-M-NW, CFP-100-M-W or CFP-100-M
CFP2-100-S Gold Support
1 Versiv Mainframe & Remote, (2) CertiFiber Pro Singlemode OLTS modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB interface cable, LinkWare Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-S
1 year of Gold Support for CFP2-100-S, CFP2-100-S-NW, CFP-100-S-W or CFP-100-S
GLD3-CFP-100-S
3 years of Gold Support for CFP2-100-S, CFP2-100-S-NW, CFP-100-S-W or CFP-100-S
CFP2-100-Q Gold Support
1 Versiv Mainframe & Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-Q
1 year of Gold Support coverage for CFP2-100-Q, CFP2-100-Q-NW, CFP-100-Q-W or CFP-100-Q
GLD3-CFP-100-Q
3 years of Gold Support coverage for CFP2-100-Q, CFP2-100-Q-NW, CFP-100-Q-W or CFP-100-Q
CFP2-100-Q with 1 year of Gold Support (available in the United States and Europe. Europe order: CFP2-100-Q/GLD INT).
Learn more about Fluke Premium Care – Gold
CFP2-100-QI Gold Support
CertiFiber Pro Quad OLTS with double ended inspection. This kit includes (2) Versiv Mainframes, (2) CertiFiber Pro Quad OLTS Modules, (2) USB fiber inspection video probes each with 4 tips, Multimode Encircled Flux compliant test reference cord kit (2m) for testing 50um LC terminated fibers (2 SC/LC, 2 LC/LC), Singlemode test reference cord kit (2m) for testing 9um LC terminated fibers (2 SC/LC, 2 LC/LC), TRC Carrying Case, (2) 1.25 mm Quick Clean Cleaners, (2) 2.5 mm Quick Clean Cleaners, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo
Learn more about Fluke Premium Care – Gold
GLD-CFP-100-Qi
1 Yr Gold Support for CFP2-100-QI, CFP-100-QI-W OR CFP-100-Qi
GLD3-CFP-100-Qi
3 Yr Gold Support for CFP2-100-QI, CFP-100-QI-W OR CFP-100-Qi
CFP2-100-QI CFP-100-QI with 1 year of Gold Support (available in the United States and Europe. Europe order: CFP2-100-QI/G INT).
Learn more about Fluke Premium Care – Gold
CERTIFIBER PRO QUAD OLTS V2, W/DOUBLE ENDED INSPECTION
Learn more about Fluke Premium Care – Gold
Accessories
CERTIFIBER PRO singlemode replacement module See Photo
VERSIV Hardsided Case See Photo
Versiv Headphones See Photo
Versiv Battery See Photo
Versiv Strap Kit See Photo
Single-mode test reference cord kit (2 m) for testing SC terminated fibers (4 SC/SC)
Single-mode test reference cord kit (2 m) for testing LC terminated fibers (2 SC/Metal LC, 2 Metal LC/Metal LC) See Photo
Single-mode test reference cord kit (2 m) for testing FC terminated fibers (2 SC/FC, 2 FC/FC)
Single-mode test reference cord kit (2 m) for testing ST terminated fibers (2 SC/ST, 2 ST/ST)
Single-mode test reference cord (2 m) for testing SC terminated fibers (SC/SC)
Single-mode test reference cord (2 m) for testing LC terminated fibers (SC/Metal LC)
Single-mode test reference cord (2 m) for testing FC terminated fibers (SC/FC)
Single-mode test reference cord (2 m) for testing ST terminated fibers (SC/ST)
Single-mode test reference cord (2 m) for testing LC terminated fibers (Metal LC/Metal LC)
Single-mode test reference cord (2 m) for testing FC terminated fibers (FC/FC)
Single-mode test reference cord (2 m) for testing ST terminated fibers (ST/ST)
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 50 µm LC terminated fibers (2 SC/Metal LC, 2 Metal LC/Metal LC) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 50 µm SC terminated fibers (4 SC/SC) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 50 µm SC terminated fibers (SC/SC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 50 µm LC terminated fibers (SC/Metal LC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 50 µm FC terminated fibers (SC/FC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 50 µm ST terminated fibers (SC/ST) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 62.5 µm LC terminated fibers (2 SC/Metal LC, 2 Metal LC/Metal LC) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 62.5 µm SC terminated fibers (4 SC/SC) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 62.5 µm SC terminated fibers (SC/SC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 62.5 µm LC terminated fibers (SC/LC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m)for testing 62.5 µm FC terminated fibers (SC/FC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode Encircled Flux compliant test reference cord (2 m) for testing 62.5 µm ST terminated fibers (SC/ST) - for use with CertiFiber Pro and SimpliFiber Pro only.
Multimode test reference receive cord (2 m) for testing 50 µm SC terminated fibers (SC/SC)
Multimode test reference receive cord (2 m) for testing 50 µm LC terminated fibers (Metal LC/Metal LC)
Multimode test reference receive cord (2 m) for testing 50 µm FC terminated fibers (FC/FC)
Multimode test reference receive cord (2 m) for testing 50 µm ST terminated fibers (ST/ST)
Multimode test reference receive cord (2 m) for testing 62.5 µm SC terminated fibers (SC/SC)
Multimode test reference receive cord (2 m) for testing 62.5 µm LC terminated fibers (Metal LC/Metal LC)
Multimode test reference receive cord (2 m) for testing 62.5 µm FC terminated fibers (FC/FC)
Multimode test reference receive cord (2m) for testing 62.5 µm ST terminated fibers (ST/ST)
FI-1000 FiberInspector USB video probe for Versiv platform.
E2000/APC bulkhead video probe tip. See Photo
LC/APC bulkhead video probe tip. See Photo
Enhanced Fiber Optic Cleaning Kit - Includes a Quick Clean 1.25mm cleaner, a Quick Clean 2.5mm cleaner, a Quick Clean MPO cleaner, a solvent pen, a cleaning cube and a softcase See Photo
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 50 µm ST terminated fibers (2 SC/ST, 2 ST/ST) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 50 µm FC terminated fibers (2 SC/FC, 2 FC/FC) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 62.5 µm ST terminated fibers (2 SC/ST, 2 ST/ST) - for use with CertiFiber Pro only.
Multimode Encircled Flux compliant test reference cord kit (2 m) for testing 62.5 µm FC terminated fibers (2 SC/FC, 2 FC/FC) - for use with CertiFiber Pro and SimpliFiber Pro only.
Single-mode test reference cord kit (2 m) for testing 9 µm SC/APC terminated fibers (2 SCUPC/SCAPC,2 SCAPC/SCAPC)
Single-mode test reference cord kit (2 m) for testing 9 µm LC/APC terminated fibers (2 SCUPC/Metal LCAPC,2 Metal LCAPC/Metal LCAPC)
FI-1000-KIT Gold Support
A USB Fiber Inspection Video probe for Versiv products plus tip set (LC, FC/SC bulkhead, 1.25 and 2.5mm universal tips in a box). See Photo
GLD-FI-1000KIT
1 year Gold Support coverage for FI-1000 KIT
GLD3-FI-1000KIT
3 years of Gold Support coverage for FI-1000 KIT
Versiv Small Carry Case. See Photo
Backpack strap for Versiv Large Case See Photo
Extended LC bulkhead video probe tip. See Photo
WiFi Adapter for Versiv Mainframe. (Available in the following countries.)
30W Power Supply, 15V, 2A with US, EU, AU, and UK adapters See Photo
30W Power Supply, 15V, 2A with US, South Africa and India adapters See Photo
South Africa and India adapters for 30W power supply See Photo
VERSIV 2 MAIN REPLACEMENT
Versiv XL case. See Photo
VERSIV V2 Main & Remote Upgrade Bundle with Wi-Fi See Photo.
VERSIV V2 Main & Remote Upgrade Bundle Non-Wi-Fi
Specifications
Power Meter Specifications
Input Connector
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type
InGaAs
Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
Integrated Wi-Fi
Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.
Loss/Length Specifications
Specification
CertiFiber Pro Multimode Modules
CertiFiber Pro Singlemode Modules
Testing Speeds (excludes referencing times)
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested
50/125 µm or 62.5/125 µm
singlemode
Source Type and Wavelengths
LED source 850 nm ± 30 nm 1300 nm ± 20 nm
Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm
Maximum Length Measurement
12 km
130 km
Length Measurement Accuracy
± 1.5 m plus ± 1 % of length
± 1.5 m plus ± 1 % of length
Output Power (Nominal)
≥ -24 dBm with EF-TRC
≥ -4 dBm
Output Power Stability3
± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes
± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes
1. At the output of the EF-TRC 2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor 3. Relative to power level after 15 minute warm up – at constant temperature
Loss/Length Specifications (continued)
Source Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5-minute warm-up.
Selected Specifications
Visual Fault Locator (VFL)
Title
Requirement
Output Power
>-5 dBm <0 dBm SMF-28 singlemode fiber Continuous wave SC/UPC connector
Operating Wavelength
650 nm nominal
Output Modes
Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter
2.5 mm universal
Laser Safety
Class II CDRH
Over operating temperature range
Environmental Specifications
Title
Requirement
Operating Temperature
-10° C to 45° C
Storage Temperature
-10° C to +60° C
Operating Relative Humidity
% RH without condensation
0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
Vibration
Random, 2 g, 5 Hz-500 Hz
Shock
1 m drop test with and without module and adapters
Safety
CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree
2
Altitude
Operating: 4,000 m; storage: 12,000 m
EMC
EN 61326–1
Documents
User documentation for Versiv firmware
Request your 4” x 6”, sturdy pocket guide that is ideal to take on all your fiber jobs. Includes a quick-action summary and checklist, this guide is an invaluable tool to ensure you never miss a critical step during your fiber testing or troubleshooting.
Case Studies
CompuCom Case Study
Challenge:
Headquartered in Dallas, Texas, CompuCom enables its customers to focus on their respective core businesses, while CompuCom handles their technology. Offering managed IT services, integration and consulting, as well as teams specializing in data centers, networks, voice and end-user environments, CompuCom supports more than four million users in North America alone. One of CompuCom's customers, a U.S.-based Top 10 Global Retailer, required a higher standard for fiber optic cable inspection, including faster testing and more comprehensive reporting. In response, CompuCom’s team turned to Fluke Networks.
Results:
As part of its service to this retailer, the CompuCom team maintains three data centers plus one backup bunker, containing nearly 20,000 servers and more than 150,000 cables. The team chose to adopt the Fluke Networks Versiv cable certification platform with a combination of the FI-7000 FiberInspector™ Pro, OptiFiber® Pro OTDR, and CertiFiber® Pro cable loss testing modules to provide easy repairs and upgrades. Since adopting the FI-7000 when it was first launched, the team has dramatically raised the standards in testing and reporting, while also simplifying test result accessibility and management. The FI-7000 enables faster test results, which have saved thousands of dollars each year. Most important, CompuCom's client has been very pleased with the higher levels of speed, quality and reliability made possible with the FI-7000. So much so, that this client now holds other service providers to similar standards.
PowerCom Empowers Technicians with LinkWare™ Live to Increase Team Efficiency Case Study
By leveraging Versiv™ DSX-5000, CertiFiber® and LinkWare™ Live, PowerCom has significantly reduced the time and effort needed to test the systems and provide results to their customers.
Challenge: PowerCOM installs and services a wide range of information and communication systems including; voice, data, Wi-Fi, security and monitoring at a variety of both indoor and outdoor locations. With over 80% of employees working in the field on multiple client sites, delivery of test results to the PowerCOM office and/or client is often challenging. Historically, the process to set up test equipment and compile results has been manual and time intensive for both field and administrative staff. Additionally, some customers desired more frequent and periodic delivery of detailed test results, rather than only upon project completion. To address these issues, PowerCOM required a solution that could help their technicians and administrative staff be more efficient, as well as readily and more easily share data with their customers.
Results: By leveraging Versiv™ DSX-5000, CertiFiber® Pro and LinkWare™ Live, PowerCom has significantly reduced the time and effort needed to test the systems and provide results to their customers. Instead of requiring the field technicians to set-up test parameters and commute to the office to deliver/review the test reports, these tasks can be done remotely through the cloud. By leveraging LinkWare Live, PowerCom technicians can complete jobs faster, ensure test accuracy and reduce the potential for rework.
Redstone Gains a Competitive Advantage with Versiv™ Family Adoption Case Study
Redstone upgraded its entire testing fleet to the new Versiv platform, including 40 DSX-5000 CableAnalyzer units, many equipped with CertiFiber Pro Optical Loss Test Set (OLTS) modules and Fiber Inspection Cameras. The company also purchased 20 OneTouch™ AT Network Assistant units.
Challenge: Redstone provides structured cabling and intelligent infrastructure management for IT data center design and implementation, and smart building deployments. The company built a reputation for excellence by focusing on service quality and performance above all else. As its reputation grew, so did customer expectations for getting more with less time and budget investment. Redstone continually seeks any advantage possible in meeting these customer demands. Network testing and certification is no exception.
Results: Redstone upgraded its entire testing fleet to the new Versiv platform, including 40 DSX-5000 CableAnalyzer™ units, many equipped with CertiFiber® Pro Optical Loss Test Set (OLTS) modules and Fiber Inspection Cameras. The company also purchased 20 OneTouch™ AT Network Assistant units. Redstone will use these new systems to test installation of more than 250,000 copper links and 25,000 fiber cores each year. Migrating to the Versiv platform saves significant time with each installation, while providing added flexibility through its interchangeable modules for copper and fiber testing.