DSX CableAnalyzer™ Series Copper Cable Certifiers
Product Highlights
Accelerates every step of the copper certification process
- Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
- ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
- Taptive™ user interface simplifies set-up, and eliminates errors
- Analyze test results and create professional test reports using LinkWare™ management software View More >
- Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
- Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
- Copper cable certifiers endorsed by cabling vendors worldwide
- Built in Alien Crosstalk testing
- Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software
PRODUCT NAVIGATION
Overview
The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.
Features
Unique Features:
- Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
- LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
- ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
- Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
- LinkWare PC management software provides unmatched analysis of test results and professional test reports
- The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem
Standards:
- Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
- Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
- TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Published Sep 2019 )
- Screen continuity along path of cabling
Performance:
- Eight second Cat 6A test time contributes to the fastest way to gain certification
- Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
- Manage up to 12,000 Cat 6A test results with full graphics
- Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
- Integrated Wi-Fi allows you to easily upload results to LinkWareTM Live
- Over 1 billion links reported on LinkWare PC management software
Manage up to 12,000 Cat 6A test results with full graphics
Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series copper cable certifiers provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.
Project menu screen shows percent complete per job. |
|
Specific screen shows up to the minute project details. |
|
Set-up or view test limits, and testing attributes. |
Capacitive touchscreen allows quick tester setup and supports all standards
Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the configuration making correct testing assured.
Simple Set up. |
Leveraging the popular and multi-featured LinkWare PC management software application, DSX CableAnalyzer Series users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project Managers have full capabilities to manage workflow and consolidate test results. Users can provide the finishing touch by adding their company logo to the report and offer it unaltered to their customers for system acceptance purposes. Keep your business tools simple, no matter which Fluke Networks copper or fiber tester you are using, LinkWare PC is the software package that reports it all.
Now with LinkWare PC stats, the new automated statistical report option, you can move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare PC test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.
LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device. With LinkWare Live, you can
- Keep track of every test on every job. Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
- Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
- Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
- Stop wasting time and gas driving testers back to the office. Integrated Wi-Fi allows you to upload your test results straight from the job site to LinkWare Live. Then download them automatically to the right job for fast report generation with LinkWare PC.
- Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
- Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.
*See supported countries.
Electrically centered plug design is compliant with TIA Level 2G and IEC Level VI accuracy requirements to 2000 MHz with a future-ready design to support all hardware upgrades
The DSX CableAnalyzer Series enables cable testing and certification for network deployments up to 40 Gigabit Ethernet – whether it is an existing Cat 5e, 6, 6A, 8 or Class I/II cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level 2G/VI accuracy required to support field testing to Cat 8 / Class I/II, 2000 MHz. The DSX exceeds the IEC Level VI and TIA Level 2G specifications assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 8 require more precise measurement to ensure they are providing the noise immunity required by 25G and 40G applications. Additionally, complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module up to 40GBASE-T testing.
The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, a key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property due to the higher level of electromagnetic interference (EMI) within the industrial environment.
Fluke Networks' DSX CableAnalyzer Series has obtained Intertek (ETL) verification in accordance with the ANSI/TIA-1152-A specification for Level 2G test equipment. (Report on file.)
Eight second Cat 6A test time and the fastest way to submit your certification results
No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.
Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.
High Definition Time Domain Crosstalk (HTDTX) shows the far end connection in clearly the issue |
Features simple diagnostics based decades |
Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The DSX CableAnalyzer Series is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in\ datacenters and Cat 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.
Wiremap - shows distance to fault, break and short
The DSX CableAnalyzer Series family copper cable certifier is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.
Copper Certification | ||
DSX-8000 CableAnalyzer™ | DSX-5000 CableAnalyzer™ | |
Category 6A / Class EA test time | 8 seconds | 10 seconds |
Category 8 / Class I/II test time | 15 seconds | |
HDTDX/HDTDR diagnostic test times | ≈ 3 seconds | ≈ 3 seconds |
Internal memory |
≈ 5,000 Cat 8 with plots ≈ 12,000 Cat 6A with plots |
≈ 12,000 Cat 6A with plots |
Level V Accuracy (1 GHz) | ✓ | ✓ |
Level VI/2G Accuracy (2 GHz) | ✓ | |
Resistance Unbalance measurement | ✓ | ✓ |
Shield integrity check | ✓ | ✓ |
TCL measurement | ✓ | ✓ |
ELTCTL measurement | ✓ | ✓ |
CDNEXT measurement | ✓ | ✓ |
CMRL measurement | ✓ | ✓ |
Built in Alien XTalk module | ✓ | ✓ |
Channel Adapter | 2 GHz Range | 1 GHz Range |
Permanent Link Adapter | 2 GHz Range | 1 GHz Range |
Optional Accessories | ||
Patch cord adapters | Category 5e, 6 and 6A patch cord | Category 5e, 6 and 6A patch cord |
Coax Adapter | ✓ | ✓ |
M12 Adapter | ✓ | ✓ |
TERA Adapter | ✓ | ✓ |
GG45 Adapter | ✓ | ✓ |
There may be scenarios where a typical four-connector channel is not used when connecting these types of devices– especially those that reside in the ceiling space where it is impractical to install a faceplate. Instead, there is just one patch cord in the telecommunications room and the permanent link is terminated at the other end with a plug so it can plug directly into the device, essentially eliminating the equipment cord. This creates what is now known as a Modular Plug Terminated Link, or MPTL.
The DSX CableAnalyzer™ is capable of certifying MPTL by using a patch cord adapter on one end and a permanent link on the opposite end (see image below).
The patch cord adapters support Category 5e, 6, and 6A performance levels and work with all DSX CableAnalyzer™ models. The latest version of the Versiv/DSX firmware is required to use the MPTL testing limits.
Validate that cables conform to international standards
The DSX2-5-IE-K1 provides complete testing for copper cabling from single pair to Cat 6A, and includes adapters for RJ-45, M12-D and M12-X. Approved by over 30 cabling manufacturers.
- Startup faster: Ensure cable performance at machine builder, commissioning and after making changes
- Prevent downtime: Find marginal cables susceptible to vibration, moisture, noise and temperature
- Speed troubleshooting: Avoid wasting time installing bypass cables. Identify the exact type and location of cable failure—or prove it’s good
- Supports cabling for EtherNet/IP™, PROFINET, ModBus TCP™ and other protocols. Supports RJ45 and M12 connectors
Support for M12 and ix Industrial® Connectors
The DSX Series offers adapters for industrial connectors, including
Models & Accessories
Models
DSX2-5000-NW Gold Support
Same configuration as the DSX2-5000 with integrated Wi-Fi disabled. Learn more about Fluke Premium Care – Gold
GLD-DSX-5000
1 year of Gold Support for DSX2-5000, DSX2-5000-NW, DSX-5000-W or DSX-5000
GLD3-DSX-5000
3 years of Gold Support for DSX2-5000, DSX2-5000-NW, DSX-5000-W or DSX-5000
DSX2-ADD-R Gold Support
1 Versiv 2 Remote, (2) DSX-5000 CableAnalyzer Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, (1) AC Charger, (2) Universal Couplers, Statement of Calibration and Getting Started Guide (Requires a Versiv 2 mainframe) See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-ADD-R
1 year of Gold Support coverage for DSX2-ADD-R or DSX-ADD-R
GLD3-DSX-ADD-R
3 years of Gold Support coverage for DSX2-ADD-R or DSX-ADD-R
DSX2-CFP-Q-ADD-R Gold Support
1 Versiv 2 Remote, (2) DSX-5000 CableAnalyzer modules, (2) CertiFiber Quad OLTS Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Large Carry Case, (1) AC Charger, (2) Universal Couplers, (2) LC/LC Simplex Adapters, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Statement of Calibration and Getting Started Guide (Requires a Versiv 2 mainframe) See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-CFP-Q-ADDR
1 year of Gold Support coverage for DSX2-CFP-Q-ADD-R or DSX-CFP-Q-ADD-R
GLD3-DSX-CFP-Q-ADD
3 years of Gold Support coverage for DSX2-CFP-Q-ADD-R or DSX-CFP-Q-ADD-R
DSX-OFP-Q-ADD Gold Support
(2) DSX-5000 CableAnalyzer Modules, OptiFiber Quad OTDR Module, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, Large Carry case, (1) AC Charger, (2) Universal Couplers, SC/SC Simplex Adapters, 2 SC/LC Multimode Launch Cables—50 µm, 2 SC/LC Singlemode Launch Cable—9 µm, (2) OTDR Hanging straps and magnets, SC/SC Simplex Adapter, LC/LC Simplex Adapter, Statement of Calibration and Getting Started Guides See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-OFP-Q-ADD
1 year of Gold Support coverage for DSX-OFP-Q-ADD
DSX-ADD Gold Support
(2) DSX-5000 CableAnalyzer Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, (1) AC Charger, (2) Universal Couplers, Statement of Calibration and Getting Started Guide See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-ADD
1 year of Gold Support coverage for DSX-ADD
GLD3-DSX-ADD
3 years of Gold Support coverage for DSX-ADD
Some of the DSX-8000 models are available in 2 versions: wireless and non-wireless. The Wireless version of the DSX-8000 includes integrated Wi-Fi for uploading results to LinkWare Live. The integrated Wi-FI is disabled in the non-wireless version for customers who do not wish to receive Wi-Fi
DSX2-8000 Gold Support
1 Versiv Mainframe & Remote, (2) DSX-8000 CableAnalyzer Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) HandStrap, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, (2) AxTalk Terminators, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8000
1 Yr Gold Support for the DSX2-8000, DSX2-8000-NW, DSX-8000-W or DSX-8000
GLD3-DSX-8000
3 Yr Gold Support for the DSX2-8000, DSX2-8000-NW, DSX-8000-W or DSX-8000
DSX2-8000 with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8000/GLD INT).
Learn more about Fluke Premium Care – Gold
DSX2-8000-NW Gold Support
Same configuration as the DSX2-8000 with integrated Wi-Fi disabled. Learn more about Fluke Premium Care – Gold
GLD-DSX-8000
1 Yr Gold Support for the DSX2-8000, DSX2-8000-NW, DSX-8000-W or DSX-8000
GLD3-DSX-8000
3 Yr Gold Support for the DSX2-8000, DSX2-8000-NW, DSX-8000-W or DSX-8000
DSX2-8000QI Gold Support
1 Versiv Mainframe & Remote, (2) DSX-8000 CableAnalyzer Modules, (2) CertiFiber Quad OLTS Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) Handstraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, (2) AxTalk Terminators, USB Video Inspection Probe w/ 4 Tips, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) LC/LC Simplex Adapters, SC/LC EF-Compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Integrated Wi-Fi , Statement of Calibration and Getting Started Guides. See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8000QI
1 Yr Gold Support for the DSX2-8000QI, DSX-8000QI-W or DSX-8000QI
GLD3-DSX-8000QI
3 Yr Gold Support for the DSX2-8000QI, DSX-8000QI-W or DSX-8000QI
DSX2-8000QI with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8000QI/G INT). Learn more about Fluke Premium Care – Gold
DSX2-8000QOI Gold Support
1 Versiv Mainframe & Remote, (2) DSX-8000 CableAnalyzer modules, (2) CertiFiber Quad OLTS modules, OptiFiber Quad OTDR module, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class 1 Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Hard sided Carry Case, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, (2) AxTalk Terminators, (2) Quick Clean Cleaners (1.25/2.50 mm), SC/SC Simplex adapters, 2 SC/LC Multimode Launch Cables—50 µm, 2 SC/LC Singlemode Launch Cable—9 µm, USB Fiber Inspection Video Probe with 4 Tips, (2) LC/LC Simplex Adapter, SC/LC EF-Compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8000QOI
1 Yr Gold Support for the DSX2-8000QOI, DSX-8000QOI-W or DSX-8000QOI
GLD3-DSX-8000QOI
3 Yr Gold Support for the DSX2-8000QOI, DSX-8000QOI-W or DSX-8000QOI
DSX2-8000QOI with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8000QOI/G INT). Learn more about Fluke Premium Care – Gold
DSX2-8000-PRO Gold Support
Versiv Professional Kit contains the DSX-8000 CableAnalyzer, CertiFiber Pro, OptiFiber Pro, Fiber Inspection and a full complement of product accessories including a Integrated Wi-Fi. Click here for a detail list of contents.
- See Photos:
- DSX CableAnalyzer
- CertiFiber Pro OLTS
- OptiFiber Pro OTDR
- Fiber inspection and cleaning
- Accessories
Learn more about Fluke Premium Care – Gold
GLD-DSX-8000PRO
1 Yr Gold Support for the DSX2-8000-PRO, DSX-8000-PRO-W or DSX-8000-PRO-W
GLD3-DSX-8000PRO
3 Yr Gold Support for the DSX2-8000-PRO, DSX-8000-PRO-W or DSX-8000-PRO-W
DSX2-8000-PRO with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8000PRO/G INT). Learn more about Fluke Premium Care – Gold
DSX2-8000MI Gold Support
1 Versiv Mainframe & Remote, (2) DSX-8000 CableAnalyzer Modules, (2) CertiFiber Multimode OLTS Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carrying Case, USB Interface Cable, (2) Universal Couplers, (2) AxTalk Terminators, USB Video Inspection Probe w/ 4 Tips, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) LC/LC Simplex Adapters, SC/LC EF-Compliant MM TRC Kit 50 µm, TRC Carry Case, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides. See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8000MI
1 Yr Gold Support for the DSX2-8000MI, DSX-8000MI-W & DSX-8000MI
GLD3-DSX-8000MI
3 Yr Gold Support for the DSX2-8000MI,DSX-8000MI-W & DSX-8000MI
DSX2-8000MI with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8000MI/G INT ). Learn more about Fluke Premium Care – Gold
Learn more about Fluke Premium Care – Gold
DSX-8000-ADD Gold Support
(2) DSX-8000 CableAnalyzer Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, (1) AC Charger, (2) Universal Couplers, (2) AxTalk Terminators, Statement of Calibration and Getting Started Guide See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8-ADD
1 Yr Gold Support for DSX-8000-ADD
GLD3-DSX-8-ADD
3 Yr Gold Support for DSX-8000-ADD
DSX2-8000-ADD-R Gold Support
1 Versiv 2 Remote, (2) DSX-8000 CableAnalyzer Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, (1) AC Charger, (2) Universal Couplers, (2) AxTalk Terminators, Statement of Calibration and Getting Started Guide (Requires a Versiv 2 mainframe) See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-8-ADD-R
1 Yr Gold Support for DSX2-8000-ADD-R or DSX-8000-ADD-R
GLD3-DSX-8-ADD-R
3 Yr Gold Support for DSX2-8000-ADD-R or DSX-8000-ADD-R
DSX2-8-CFP-Q-ADD/R Gold Support
1 Versiv 2 Remote, (2) DSX-8000 CableAnalyzer modules, (2) CertiFiber Quad OLTS Modules, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class I Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Carry Case, (1) AC Charger, (2) Universal Couplers, (2) AxTalk Terminators, (2) LC/LC Simplex Adapters, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Statement of Calibration and Getting Started Guide. (Requires a Versiv 2 mainframe) See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX8-CFPQADD/R
1 Yr Gold Support for DSX2-8-CFP-Q-ADD/R or DSX-8-CFP-Q-ADD/R
DSX2-5000 Gold Support
1 Versiv Mainframe & Remote, (2) DSX-5000 CableAnalyzer Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) HandStrap, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.. See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-5000
1 year of Gold Support for DSX2-5000, DSX2-5000-NW, DSX-5000-W or DSX-5000
GLD3-DSX-5000
3 years of Gold Support for DSX2-5000, DSX2-5000-NW, DSX-5000-W or DSX-5000
DSX2-5000 with 1 year of Gold Support (available in the United States and Europe. Europe order: DSX2-5000/GLD INT). Learn more about Fluke Premium Care – Gold
DSX2-5000QI Gold Support
1 Versiv Mainframe & Remote, (2) DSX-5000 CableAnalyzer Modules, (2) CertiFiber Quad OLTS Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) Handstraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, USB Video Inspection Probe w/ 4 Tips, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) LC/LC Simplex Adapters, SC/LC EF-Compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Integrated Wi-Fi, Statement of Calibration and Getting Started Guides.See Photo.
Learn more about Fluke Premium Care – Gold
GLD-DSX-5000Qi
1 year of Gold Support for DSX2-5000QI or DSX-5000Qi
GLD3-DSX-5000Qi
3 years of Gold Support for DSX2-5000QI or DSX-5000Qi
DSX2-5000QI with 1 year of Gold Support (available in the United States and Europe. Europe order: DSX2-5000QI/G INT)
Learn more about Fluke Premium Care – Gold
DSX2-8000QOI with integrated Wi-Fi disabled with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8QOI/G-NW IN).
Learn more about Fluke Premium Care – Gold
Same configuration as the DSX2-8000-PRO with integrated Wi-Fi disabled. Learn more about Fluke Premium Care – Gold
DSX2-8000-PRO with integrated Wi-Fi disabled with 1 year Gold Support (available in the United States and Europe only. Europe order: DSX2-8-PRO/G-NW IN). Learn more about Fluke Premium Care – Gold
DSX2-5-IE-K1 Gold Support
DSX2-5-IE-K1, 1 Versiv Mainframe & Remote, (2) DSX-5000 Copper CableAnalyzer Modules, Set of Cat 6A/Class EA Channel Adapters, Set of M12X adapters, Set of M12D adapters, Reference Module, (2) Headsets, (2) Hand strap, (2) Shoulder Straps, Carry Case, USB Interface Cable, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. Since Permanent Link adapters are not included, the Reference Module is used to set-ref. See Photo
Learn more about Fluke Premium Care – Gold
GLD-DSX2-5-IE-K1
GLD-DSX2-5-IE-K1, 1 YR Gold Support, DSX2-5-IE-K1
GLD3-DSX2-5-IE-K1
GLD3-DSX2-5-IE-K1, 3 YR Gold Support, DSX2-5-IE-K1
2GHZ DSX QUAD OLTS INSPC V2. Learn more about Fluke Premium Care – Gold
DSX2-8QOI-NW Gold Support
DSX2-8000QOI with integrated Wi-Fi disabled. Learn more about Fluke Premium Care – Gold
GLD-DSX-8000QOI 1 Yr Gold Support for the DSX2-8000QOI, DSX2-8QOI-NW or DSX-8000QOI
GLD3-DSX-8000QOI 3 Yr Gold Support for the DSX2-8000QOI, DSX2-8QOI-NW or DSX-8000QOI
Learn more about Fluke Premium Care – Gold
Accessories
DSX CAT 6A/CLASS EA PLA SET See Photo
DSX TERA CAT 7A/CLASS FA PLA SET See Photo
DSX CAT 6A/CLASS EA CHA SET See Photo
DSX TERA Cat 7A/CLASS FA CHA SET See Photo
Versiv Headphones See Photo
VERSIV Hardsided Case See Photo
Versiv Battery See Photo
Versiv Strap Kit See Photo
DSX Patch Cord Test Adapter Set for Category 6A patch cords
Versiv Small Carry Case. See Photo
Backpack strap for Versiv Large Case See Photo
DSX Coax Adapter See Photo
DSX M12-D 4-Position Adapter set See Photo
WiFi Adapter for Versiv Mainframe. (Available in the following countries.)
DSX-8000 Cat 8/Class I PLA Set. See Photo
DSX-8000 2GHz Set-Ref Module
DSX-PLA804 Plug replacement parts. This item includes two contact blocks of the 8-pin modular plug.
DSX-PLA004 plug replacement parts. This item includes two contact blocks of the 8-pin modular plug
30W Power Supply, 15V, 2A with US, EU, AU, and UK adapters See Photo
30W Power Supply, 15V, 2A with US, South Africa and India adapters See Photo
South Africa and India adapters for 30W power supply See Photo
DSX-8000 TERA CHANNEL ADAPTER SET See Photo
DSX-8000 TERA PERMANENT LINK ADAPTER SET See Photo
DSX-8000 TERA PERMANENT LINK AND CHANNEL ADAPTER SET See Photo
SINGLE DSX CAT 6A/CLASS EA PERMANENT LINK ADAPTER
SET OF TWO SHIELDED CAT 5E REPLACEMENT PATCH CORD JACKS
SET OF TWO SHIELDED CAT 6 REPLACEMENT PATCH CORD JACKS
SET OF TWO SHIELDED CAT 6A REPLACEMENT PATCH CORD JACKS
DSX M12-X 8-Position Adapter set See Photo
DSX-8000-MOD,2GHZ DSX MODULE REPLACEMENT 1 UNIT
DSX ALIEN CROSSTALK LINK TERMINATORS - SET OF 2
VERSIV 2 MAIN REPLACEMENT
Versiv XL case. See Photo
VERSIV V2 Main & Remote Upgrade Bundle with Wi-Fi See Photo.
VERSIV V2 Main & Remote Upgrade Bundle Non-Wi-Fi
Single Permanent Link Adapter for DSX2-8000 See Photo.
Single Channel Adapter for DSX2-8000 See Photo.
Single Channel Adapter for DSX2-5000 See Photo.
Specifications
Cable Types
Shielded and unshielded pair LAN cabling
TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adapters
Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters
Jack type: shielded RJ45
Optional Jack type: Tera, GG45
Test Standards
TIA
Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D
ISO/IEC
Class C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequency
DSX-8000: 2000 MHz;
DSX-5000: 1000 MHz
General Specifications
Speed of Autotest
DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)
Input protection
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display
5.7 in LCD display with a projected capacitance touchscreen
Case
High impact plastic with shock absorbing overmold
Dimensions
Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight
Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote:
Lithium ion battery pack, 7.2 V
Typical battery life:
8 hours
Charge time*
Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported
English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration
Service center calibration period is 1 year
Integrated Wi-Fi
Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental Specifications
Operating Temperature
32°F to 113°F (0°C to 45°C)
Storage Temperature
-14°F to +140°F (-10°C to +60°C)
Operating relative humidity
0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
Vibration
Random, 2 g, 5 Hz-500 Hz
Shock
1 m drop test with and without module and adapter
Safety
CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude
13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMC
EN 61326-1
Performance Specifications **
DSX-8000
Category 8 test modes (or lower link categories)
Class I/II test modes
ANSI/TIA-1152 Level 2G
Proposed standard IEC 61935-1 Ed. 5 Level VI
DSX-5000
Category 6A/Class EA test modes (or lower link categories)
Class FA test modes
Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling1
Without Remote or in DSX-5000 Long Communication Mode
With Remote
Range
800 m (2600 ft)
150 m (490 ft)
Resolution
0.1 m or 1 ft
0.1 m or 1 ft
Accuracy
± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation Delay
Without Remote or in DSX-5000 Long Communication Mode
With Remote
Range
4000 ns
750 ns
Resolution
1 ns
1 ns
Accuracy
± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay Skew
Range
0 ns to 100 ns
Resolution
1 ns
Accuracy
± 10 ns
DC Loop Resistance Test
Range
0 Ω to 540 Ω
Resolution
0.1 Ω
Accuracy
± (1 Ω + 1 %)
Overload recovery time
Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Documents
By Panduit and Fluke Networks
User documentation: M12 4-Position D-Coded and 8-Position X-Coded Adapters for Industrial Ethernet
User documentation
User documentation for Versiv firmware
These copyright notices and software licenses apply to portions of the firmware used in the Versiv suite of cabling certification products. The open source software files are on the DVD provided with the product. You do not need these files to use the Versiv products.
This document describes how to completely clear the product's memory. Applies to DSX, CertiFiber Pro, OptiFiber Pro, and FiberInspector Pro products.
Radio frequency compliance information for products that have Wi-Fi radios.
Case Studies
ITM's Fibre & Equipment Engineer reviews their newly purchased Fluke Networks Versiv Case Study
ITM, a UK-based leading independent provider of specialist ICT infrastructure solutions and services, applies best of breed technology, in-house expertise and innovation to deliver standards compliant solutions and services to clients throughout the UK, Europe and the rest of the World. Stuart Ayres, ITM Fibre & Equipment Engineer, reviewed the results of their investment in twenty Versiv Cabling Certification Systems.
After using the Versiv System for a few months it clearly offers several advantages when compared to the previous generation of test equipment. Not only is the Versiv System faster, the modular design and online connectivity dramatically reduces our engineers travel time as they no longer need to call into the office to have test results downloaded or firmware updated.
During the few months that we have been using the new equipment I have identified the following advantages that translate into productivity gains for both ITM and our Customers:
- Greatly reduced test cycle times for both copper and fibre.
- Easy and fast movement of test data from site to office enables better project progress reporting, quicker sign-off and invoicing.
- Ability to remotely configure and control the test units.
- Simplified logistics, we now only have to maintain one fleet of modular multi-purpose test equipment.
PowerCom Empowers Technicians with LinkWare™ Live to Increase Team Efficiency Case Study
By leveraging Versiv™ DSX-5000, CertiFiber® and LinkWare™ Live, PowerCom has significantly reduced the time and effort needed to test the systems and provide results to their customers.
Challenge: PowerCOM installs and services a wide range of information and communication systems including; voice, data, Wi-Fi, security and monitoring at a variety of both indoor and outdoor locations. With over 80% of employees working in the field on multiple client sites, delivery of test results to the PowerCOM office and/or client is often challenging. Historically, the process to set up test equipment and compile results has been manual and time intensive for both field and administrative staff. Additionally, some customers desired more frequent and periodic delivery of detailed test results, rather than only upon project completion. To address these issues, PowerCOM required a solution that could help their technicians and administrative staff be more efficient, as well as readily and more easily share data with their customers.
Results: By leveraging Versiv™ DSX-5000, CertiFiber® Pro and LinkWare™ Live, PowerCom has significantly reduced the time and effort needed to test the systems and provide results to their customers. Instead of requiring the field technicians to set-up test parameters and commute to the office to deliver/review the test reports, these tasks can be done remotely through the cloud. By leveraging LinkWare Live, PowerCom technicians can complete jobs faster, ensure test accuracy and reduce the potential for rework.
Redstone Gains a Competitive Advantage with Versiv™ Family Adoption Case Study
Redstone upgraded its entire testing fleet to the new Versiv platform, including 40 DSX-5000 CableAnalyzer units, many equipped with CertiFiber Pro Optical Loss Test Set (OLTS) modules and Fiber Inspection Cameras. The company also purchased 20 OneTouch™ AT Network Assistant units.
Challenge: Redstone provides structured cabling and intelligent infrastructure management for IT data center design and implementation, and smart building deployments. The company built a reputation for excellence by focusing on service quality and performance above all else. As its reputation grew, so did customer expectations for getting more with less time and budget investment. Redstone continually seeks any advantage possible in meeting these customer demands. Network testing and certification is no exception.
Results: Redstone upgraded its entire testing fleet to the new Versiv platform, including 40 DSX-5000 CableAnalyzer™ units, many equipped with CertiFiber® Pro Optical Loss Test Set (OLTS) modules and Fiber Inspection Cameras. The company also purchased 20 OneTouch™ AT Network Assistant units. Redstone will use these new systems to test installation of more than 250,000 copper links and 25,000 fiber cores each year. Migrating to the Versiv platform saves significant time with each installation, while providing added flexibility through its interchangeable modules for copper and fiber testing.
LanTroVision Adopts the Versiv™ DSX-5000 CableAnalyzer™ Case Study
Migrating from the Fluke Networks DTX-1800 CableAnalyzer to the new Versiv DSX-5000 product line was caused less by a challenge and more by an opportunity to adopt a next-generation technology that leveled the playing field against shrinking budgets and project schedules.
Challenge: LanTroVision is a Singapore-based structured cabling and IT network installation company with subsidiaries and alliance partnerships across Asia, Australia, Africa, Europe, and South America. With annual revenue exceeding $106.8 million USD (S$133.54 million), LanTroVision is focused on continual growth by providing evolving product and service lines that meet or exceed customer expectations. The company has established a legacy of providing best-in-class network and cable infrastructure services, but maintaining this legacy grows more-and-more challenging as customer expectations increase despite shrinking budgets and project schedules. The company is constantly asked to do more with less.
Results: Migrating from the Fluke Networks DTX-1800 CableAnalyzer to the new Versiv DSX-5000 product line was caused less by a challenge and more by an opportunity to adopt a next-generation technology that leveled the playing field against shrinking budgets and project schedules. The Versiv DSX-5000 helps LanTroVision complete cable installation jobs to customer specifications in half the time. It allows them to test all kinds of cables used on the job and maintain maximum uptime in customer networks, all with little-to-no technician training. In addition, the DTX and DSX platforms are interoperable, allowing LanTroVision to make the most of their investments and migrate technologies as their budget and schedule allows.
Endorsement
|
Learn more ETL Verified to IEC Level V
Gold Product Support
Gold Support for your DSX CableAnalyzer™ allows you to make the most of your DSX CableAnalyzer purchase while ensuring a higher return on your investment. You will minimize your downtime, receive faster trouble resolution and have total access to all support resources.
What do you get with Gold Support for your DSX CableAnalyzer and Fiber bundles?
Benefits | Standard Warranty | Gold Support |
---|---|---|
Loaner Equipment Service* | ||
Web and Email | Web, Email and Phone | |
< 24 Hours | < 2 Hours | |
Primary Case Handling | 7am-5pm (PST) | 24 x 7 x 365 |
Customer Service | Technical Support | |
*Available in certain geographies currently
**Applies to accessories in the original product purchase
ISO 9001 standards compliance requires the unit be calibrated per manufacturer’s recommendations, which is annually for the DSX. Keeping your DSX CableAnalyzer and Fiber bundles calibrated is critical to ensure accuracy when testing copper and fiber networks. Our calibration processes are ISO-9001 controlled and designed to certify that your DSX CableAnalyzer and Fiber bundles meet all published specifications. To receive a loaner unit during calibration (available in most regions), we recommend you schedule your appointment 6 weeks in advance of your required calibration date. If a loaner is not required or calibration cannot be scheduled in advance, Gold customers may opt to instead receive a shipping waybill and calibrations will receive priority turnaround. Typical turnaround time for a calibration is 5 working days. Your DSX and Fiber bundles will be precisely calibrated to factory specifications (calibration certificate provided - calibration traceable with data available for extra charge), repaired as necessary with genuine OEM repair parts, upgraded with all of the latest software and firmware then cleaned and performance verified. In addition, all accessories that came with your DSX CableAnalyzer and Fiber bundles will be tested and replaced if faulty or defective.
If your DSX CableAnalyzer and Fiber bundles should fail, we'll deliver a loaner unit via next business day delivery to keep you up and running. We'll repair your DSX and Fiber bundles and replace defective accessories that came with your unit at no charge, with "first on bench" priority, and return it to you - all shipping paid by Fluke Networks.
Some accessories are essential to testing and certifying cable. If any accessory that comes with your DSX CableAnalyzer or Fiber bundles are qualified as defective or faulty by our technical assistance center, it will be replaced free of charge. Universal Permanent Link Adapters and Modules are limited to replacement of one set per year, provided they have met the aforementioned criteria.
Extend the expertise of your staff. Gold Support includes priority access to our world-class Technical Assistance Center (TAC). Our centers in Seattle, WA and Eindhoven, NL employ a full staff of highly trained technical experts that are on call, including weekends and through the night, to answer complex troubleshooting questions, including GOLD only services such as: Test set-up and instrument configuration, Fiber testing and reference setting, Test results interpretation, including trace results analysis. Let us help you get the most out of your DSX CableAnalyzer and Fiber bundles and understand the results you are seeing.
Your membership qualifies you for “Members Only” promotions and programs. This includes product discounts, access to reconditioned equipment at special prices and other incredible values.
Ensure that you are getting the most out of your DSX CableAnalyzer and Fiber bundles with Gold Support Services. Gold Support must be purchased for the DSX CableAnalyzer and Fiber bundles for complete coverage.